CONMACO |
CABLE CONNECTED PILE HAMMER |
SPECIFICATIONS |
|
MODEL |
50E5 |
65E5 |
80E5 |
100E5 |
115E5 |
125E5 |
200E5 |
300E5 |
Rated Striking Energy - Maximum - Ft. Lbs. |
25,000 |
32,500 |
40,000 |
50,000 |
57,500 |
62,500 |
100,000 |
150,000 |
Weight of Striking Parts - Nominal - Lbs. |
5,000 |
6,500 |
8,000 |
10,000 |
11,500 |
12,500 |
20,000 |
30,000 |
Stroke Length - Maximum - Inches |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
Blows/Minute at Refusal (Maximum Stroke) {a) |
48 |
50 |
47 |
47 |
42 |
41 |
46 |
40 |
Steam Consumption @ 212o F(at hammer) - PSI {c} |
1,918 |
2,584 |
2,623 |
3,155 |
2,863 |
3,229 |
6451 |
7523 |
Operating Pressure (at Hammer) - PSI |
70 |
95 |
80 |
100 |
100 |
100 |
110 |
150 |
Air Consumption (Adiabatic - at hammer) SCFM {b} |
560 |
700 |
740 |
850 |
770 |
875 |
1700 |
1900 |
Inlet Connection - Dia. In Inches (NPT) |
2 |
2-1/2 |
2-1/2 |
2-1/2 |
2-1/2 |
2-1/2 |
4 |
4 |
Distance between Jaws - Inches |
20 |
20 |
26 |
26 |
26 |
26 |
56 |
56 |
Jaw Width - Inches {d} |
8-1/4 |
8-1/4 |
9-1/4 |
9-1/4 |
9-1/4 |
9-1/4 |
11-1/4 |
11-1/4 |
Length of Hammer (without helmet) |
16'10" |
16''10" |
17'9" |
17'9" |
17'9" |
18'0" |
19'1" |
20'10" |
Width of Hammer - Inches |
31-1/4 |
31-1/4 |
35-3/16 |
35-3/16 |
35-3/16 |
35-3/16 |
61-1/4 |
61-1/4 |
Depth of Hammer - Inches |
39 |
47-3/4 |
42-1/8 |
49-7/16 |
53 |
53 |
53 |
53 |
Weight of Hammer - Lbs. |
11,000 |
12,500 |
17,500 |
19,500 |
21,000 |
22,000 |
47,170 |
58,400 |
Size of Hoisting Line - Dia. In Inches |
3/4 |
3/4 |
7/8 |
7/8 |
7/8 |
7/8 |
-- |
-- |
|
MODEL |
50 |
65 |
80 |
100 |
115 |
|
Rated Striking Energy - Maximum - Ft. Lbs. |
15,000 |
19,500 |
26,000 |
32,500 |
37,375 |
Blows per Minute - Normal Stroke & No Set {a} |
60 |
60 |
50 |
50 |
50 |
Inlet Pressure at Hammer - PSI |
80 |
100 |
85 |
100 |
120 |
Normal Stroke - Inches |
36 |
36 |
39 |
39 |
39 |
Volume of Free Air - CFM - adiabatic {b} |
565 |
625 |
850 |
950 |
1060 |
Steam Consumption @ 212o F(at hammer) - PSI {c} |
1,925 |
2,300 |
3,000 |
3,425 |
3,980 |
Inlet Connection - Dia. In Inches |
2 |
2 |
2-1/2 |
2-1/2 |
2-1/2 |
Head Sheave Groove Diameter |
3/4 |
3/4 |
7/8 |
7/8 |
7/8 |
Distance between Jaws - Inches |
20 |
20 |
26 |
26 |
26 |
Jaw Width - Inches {d} |
8-1/4 |
8-1/4 |
9-1/4 |
9-1/4 |
9-1/4 |
Length of Hammer (without helmet) |
13''0" |
13'0" |
15'0" |
15'0" |
15'0" |
Weight of Striking Parts - Lbs. |
5,000 |
6,500 |
8,000 |
10,000 |
11,500 |
Weight of Hammer - Lbs. |
9,700 |
11,200 |
16,700 |
18,700 |
20,250 |
{a} Hammer operating speed is a function of many variables, including penetration
resistance, cushion material, pressure, stroke, etc. Observed blow-count will vary depending on driving conditions. Energy is not a function of speed. |
{b} Compressor output must exceed air required at hammer due to line and
efficiency losses. It is advisable that the adiabatic consumption figure be increased by approximately 30% in the determination of the of the required compressor size. |
{c} Steam consumption is based on feedwater and steam temperature of 212o
F. |
{d} Standard Female Jaw dimensions are shown. Male Jaws are available on special order. |
|